<p dir="ltr">This repository contains the results dataset from the work presented in [this] paper. </p><p dir="ltr">Additional information on the mathematical model formulation, the energy technologies considered, and the case studies can be found <a href="https://doi.org/10.1016/j.jclepro.2024.141465" rel="noreferrer" target="_blank">here</a>.</p><h2>Repository Structure</h2><p dir="ltr">The repository is divided into folders with the following naming conventions:</p><h3>Enabled Technologies</h3><ul><li><b>All</b>: all energy technologies enabled </li><li><b>NoDER</b>: all energy technologies enabled except for PV and BES </li><li><b>El</b>: all energy technologies enabled and a fully-electrified building </li></ul><h3>Case</h3><ul><li><b>D</b>: both technology design and operations are optimised </li><li><b>O</b>: only operations is optimised</li></ul><h3> Thermal Comfort Management</h3><ul><li><b>TS</b>: Tight setpoint without pre-heating/cooling </li><li><b>TP</b>: Tight setpoint with pre-heating/cooling </li><li><b>LP</b>: Loose setpoint with pre-heating/cooling </li></ul><p dir="ltr"><i>Note: `Par` refers to runs with a sweep of the emissions constraint to generate Pareto fronts.</i></p><h2>File Description</h2><p dir="ltr">Each folder contains the following `.csv` results files, each with a subset of relevant information tied to its name:</p><ul><li>`out_building`</li><li>`out_cost`</li><li>`out_flows`</li><li>`out_storage`</li><li>`out_supply`</li></ul><h3>Run_ID Format</h3><p dir="ltr">The column `Run_ID` contains a full description of the runs performed, encoded as follows:</p><h4>Case</h4><ul><li> `DesOp`: design and operations optimisation </li><li> `Op`: operations optimisation only</li></ul><h4>Electricity Tariff</h4><ul><li> `flat`: flat </li><li> `TOU`: time-of-use </li><li> `dem`: demand-aware</li></ul><h4>Thermal Comfort Management: see above</h4><h4>Enabled Technologies: see above</h4><h4>Building Vintage, Type, and Site </h4><ul><li> `b1`: old house Melbourne </li><li> `b2`: new house Melbourne </li><li> `b3`: old apartment Melbourne </li><li> `b4`: new apartment Melbourne </li><li> `b5`: old house Brisbane </li><li> `b6`: new house Brisbane </li><li> `b7`: old apartment Brisbane </li><li> `b8`: new apartment Brisbane </li></ul><p dir="ltr"><i>Note: Technology naming follows the convention reported </i><a href="https://doi.org/10.1016/j.jclepro.2024.141465" rel="noreferrer" target="_blank"><i>here</i></a>.</p><h2>Contact</h2><p dir="ltr">Any additional information required to reanalyse the data reported in this paper or reproduce the results is available from the corresponding author upon request.</p>